– Fairly priced.

Auction products.

Bid on Prisma for our current storage products.

Haidach SY 25/26/27 III (3) – 2 TWh

Haidach SY 25/26/27 III (3) – 2 TWh

Storage

Haidach (market area THE)

Allocation date

07/11/2024, 11:00–11:30 CET

Contract period

01/04/2025 – 01/04/2027

Allocation mode/Pricing

Pay-as-bid

Plattform

PRISMA

Capacity on offer

2 TWh

Structure (firm)***

158 / 132 days

Structure (firm + interr.)****

106 / 100 days

view more

Contact for Marketing Enquiries

Tel.: +49 561 99858-7174
Tel.: +49 561 99858-7178
E-mail: sales@sefe-storage.de

Bundle structure

Volume firm

Volume interr.

Injection firm

Injection interr.

Withdrawal firm

Withdrawal interr.

35,143,453 kWh

10,786 kWh/h

5,304 kWh/h

12,099 kWh/h

3,991 kWh/h

Price model

Storage feeFixed price
Variable injection fee

0 €/MWh

Variable withdrawal fee

0 €/MWh

Service fee

0 €

  

Conditions

Renomination lead time connection point

2 h

Connection Point

Market Area

TSO

Name

Offered Capacity Products

THE

bayernets GmbH

BAY-700069-8021-1/
BAY-700069-8021-2

FZK, bFZKtemp, DZK, UBK 

THE

Open Grid Europe GmbH

3433P/3433I

bFZKtemp, UBK

Injection Curve

Working Gas Volume greater than or equal to 70%:
IR [%] = WGV [%] x (–2) + 240

Withdrawal Curve

Working Gas Volume lower than or equal to 30%:
WR [%] = WGV [%] x 1.3333 + 60

Miscallaneous / Comments

Allocation of capacity a few minutes after closing.

The respective current filling level requirements have to be considered.

The use of the capacity restricted by curves is no longer free of charge and is billed according to the regulation in the storage specification.

open PRISMA Capacity Platform

Additional capacities and services

Additional capacities

There is more for you. Short-term capacities from within-day to all year round. 

view more

Remit

Time is money. We take over your storage status report to the authorities.  

view more

*** min. time to fully inject/withdraw using firm rates with consideration of storage curves
**** min. time to fully inject/withdraw using firm and interruptible rates with consideration of storage curves